Description

MRCOOL Hyper Heat 2nd Gen 48K BTU, 4 Ton, 16.5 SEER2 Heat Pump Condenser and Ducted Air Handler with 15 Ft. R-454B No-Vac Lineset – CENTRAL-48-HP-230B15

The MRCOOL Central Heat Pump & Air Conditioner Bundle is a heating and cooling system you need to stay warm in winter, cool in summer, and energy efficient all year long.

Features
  1. MRCOOL Hyper Heat 2nd Gen 48K BTU, 4 Ton, 16.5 SEER2 Central Ducted Condenser

  2. MRCOOL VersaPro 2nd Gen 48K BTU, 4 Ton Central Ducted Air Handler

  3. MRCOOL 15 Ft. R-454B No-Vac Lineset

1. MRCOOL Hyper Heat 2nd Gen 48K BTU, 4 Ton, 16.5 SEER2 Central Ducted Condenser (CENTRAL-48-HP-C-230B00-O)

  • R-454B refrigerant

  • 10-year warranty, covering the compressor, parts, and labor

2. MRCOOL VersaPro 2nd Gen 48K BTU, 4 Ton Central Ducted Air Handler (MVP-48-HP-MUAH-230A00-O)

  • Utilizes R-454B refrigerant, and an optional heat kit

  • 10-year warranty

3. MRCOOL 15 Ft. R-454B No-Vac Lineset (NV15-3834-O)

  • Kink Resistant – Precharged

  • Simple Secure Quick Connect

  • UV Protected Insulation

  • Works With: VersaPro 2nd Gen – Central Ducted Hyper Heat 2nd Gen

4. MRCOOL Smart Thermostat (MST04)

  • Ensure ideal temperature with presets for Home, Away, and Sleep that perfectly align to match your specific needs and preferences.

  • One App for All Your HVAC Systems

  • Global Control for Remote Accessibility

  • Works with Alexa, Google, Siri, and MRCOOL® Link

Specifications
Condenser
Dimensions 16.34″ D x 38.39″ H x 38.58″ W
SEER2 16.5
Tonnage 4
Cooling Capacity (BTU) 48000
Heating Capacity (BTU) 50000
Voltage (V) 208-230
Refrigerant Type R454B
Air Handler
Dimensions 24.49″ D x 52.99″ H x 21.02″ W
Tonnage 4
Cooling Capacity (BTU) 48000
Heating Capacity (BTU) 48000
Voltage (V) 115/208-230
Lineset
Dimensions 30″ D x 30″ H x 5″ W
Refrigerant Type R-454B
Refrigerant Volume (Oz) 2.11
Line Set Length 15ft
Lineset Fitting Type Quick-Connect
Liquid Line Size 3/8
Suction Line Size 3/4
What our Experts Think
  • Powerful Year-Round Comfort – 48,000 BTU (4 Ton) heat pump delivers efficient heating and cooling for medium-to-large homes.

  • Energy-Efficient Performance – 16.5 SEER2 ensures lower utility costs while maintaining reliable climate control.

  • 15 Ft. R-454B No-Vac Lineset – Pre-charged line set simplifies installation and reduces labor time.

  • Ducted Air Handler – Integrates seamlessly with existing ductwork for whole-home comfort.

  • Durable & Quiet – 2nd Gen design ensures long-lasting, low-noise operation.

Q&A

Q: What is included in this MRCOOL Hyper Heat 2nd Gen system?
A: It includes a 48,000 BTU (4 ton) heat pump condenser, ducted air handler, and a 15 ft. pre-charged R-454B No-Vac lineset for simplified installation.

Q: How energy efficient is the system?
A: With a 16.5 SEER2 rating, it delivers efficient cooling and heating while reducing energy costs.

Q: Can it provide both heating and cooling?
A: Yes, the heat pump condenser provides year-round comfort with both heating and cooling capabilities.

Q: What makes the No-Vac lineset beneficial?
A: The pre-charged R-454B No-Vac lineset simplifies installation by eliminating the need for vacuum pumps or additional refrigerant charging.

Q: What size area can it cover?
A: Ideal for medium to large homes up to approximately 2,000–2,500 sq. ft., depending on insulation and climate.

Q: Who should choose this system?
A: Homeowners looking for a powerful, energy-efficient central HVAC system with easy installation and reliable year-round performance.

Maintenance Tips
  • Air Filter Care: Replace or clean indoor filters every 1–3 months to maintain airflow and efficiency.

  • Outdoor Unit Maintenance: Keep condenser free of leaves, dirt, and debris.

  • Ductwork Inspection: Seal leaks and clean ducts for consistent air distribution.

  • Condensate Drain: Check and clear drain lines regularly to prevent water buildup.

  • Coil Cleaning: Schedule annual cleaning of evaporator and condenser coils for peak performance.

  • Lineset Check: Inspect the 15 ft. R-454B No-Vac lineset for proper installation, insulation, and integrity.

  • Professional Service: Schedule yearly maintenance to maintain 16.5 SEER2 efficiency and extend system lifespan.